| Datenblatt-Suchmaschine für elektronische Bauteile |
|
ZIOL2102 Datenblatt(PDF) 89 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
ZIOL2102 Datenblatt(HTML) 89 Page - List of Unclassifed Manufacturers |
|
89 / 91 page ![]() ZIOL2xxx – IC Family IO-Link compliant HV Line Driver IC Family Data Sheet January 31, 2012 © 2012 Zentrum Mikroelektronik Dresden AG — Rev. 2.2.1 All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The information furnished in this publication is PRELIMINARY and subject to changes without notice. 89 of 90 Appendix C ZIOL2xxx Line Fail Detector The following description of the Line-Fail (LF) Detection feature assumes the utilization of both channels in device mode. In the case one channel is used only, the number of failures that can be detected with the LF detector will be reduced accordingly. The following supply failures (Table 10.1) shall be detected or shall not cause undefined or malfunctions of the device (sensor/actuator). For more information about the Line-Fail detector as part of the Power-Fail detection feature of the ZIOL2xxx ICs, please refer to chapter 3.5. Table 10.1 Abnormal Power Supply Situations Number Failure IC Supply IC function F1 L+ break F2 L- break F3 L+ and L- break After the break occurred the IC is supplied by the decoupling caps which are between VDD and VSS and LR_OUT and VSS, respectively. In addition to that the IC might get “supply power” via incoming (toggling) cable signals. As long as the IC has sufficient supply power (which is normally - at least for some milliseconds - the case), the LF function will detect this as LINE_FAULT event and will rise an exception. This exception can be signaled to the µC via the INT_L signal if configured accordingly. Customer recommendation: Subsequently the µC shall stop any communication and shall handle (e.g. signal) the power fail situation. F4 24V power supply falsely interconnected to COM/AUX in combination with F1, F2, or F3. The IC is permanently powered via the COM/AUX external protection diodes (and internal parasitic diodes). The LF function will detect this as LINE_FAULT event and will raise an exception. This exception can be signaled to the µC via the INT_L signal if configured accordingly. Customer recommendation: Subsequently the µC shall stop any communication and shall handle (e.g. signal) the power fail situation (e.g. by influencing signaling LEDs). F5 Correct interconnection of the 24V power supply to L+ and L- but in addition to that is the 24V power supply falsely interconnected No difference to the regular power supply situation. The LF detector will not act in this situation. However, the IC protection is provided by the overload and over temperature protection feature. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |