| Datenblatt-Suchmaschine für elektronische Bauteile |
|
AD6652BBC Datenblatt(PDF) 47 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD6652BBC Datenblatt(HTML) 47 Page - Analog Devices |
|
47 / 76 page ![]() AD6652 Rev. 0 | Page 47 of 76 CHANNEL 0 START SYNC MULTIPLEXER CHANNEL 0 HOP SYNC HOP EXT ADD 5:5 SOFT SYNC0 EXT ADD 5:0 SELECT LINES FROM NCO CONTROL REGISTER TO START HOLD-OFF COUN D EXT ADD 4:5 SELECT LINES FROM NCO CONTROL REGISTER TO NCO HOLD-OFF COUNT Note that Multiple Qualifiers Are Required to Enable MULTIPLEXER START EXT ADD 5:4 SOFT SYNC0 EXT ADD 5:0 TER ER START SYNC ENABLE, 0x82:0 AND EXT ADD 4:4 A NCB SYNCC SYNCD 0x88:8 0x88:7 HOP SYNC ENABLE, 0x82:1 AN SYNCA SYNCB SYNCC SYNCD 0x88:8 0x88:7 PIN SYNC_EN B* PIN SYNC_EN C* PIN SYNC_EN D* SYNCB PIN SYNCC PIN SYNCD PIN * FROM EXTERNAL MEMORY ADDRESS REGISTER 4:3-0 NOTE: ALL CIRCUITRY AND SIGNALS ARE IDENTICAL AND REPEATED FOR EACH CHANNEL EXCEPT SOFT SYNCx. SOFT SYNCx CONTROL SIGNALS ARE ASSIGNED TO A SINGLE CHANNEL AND ARE NOT SHARED WITH ANY OTHER CHANNEL. Figure 53. Synchronizing Signal Routing Example, Channel 0 ; either a Pin_Sync or a Soft_Sync Signal to Be Routed Start with Soft Sync The AD6652 includes the ability to synchronize channels or chips using the microport. One action to synchronize is the start of channels or chips. The start update hold-off counter (0x83) in conjunction with the start bit and sync bit (External Address 5) allows this synchronization. The start update hold- off counter delays the start of a channel by the 16-bit value programmed at 0x83 (number of AD6652 CLK periods Use the following me multiple reset to the SYNC SY PIN SYNC_EN A* SYNCA PIN AD6652 HARDWARE AND SOFTWARE SYNC CONTROL FOR ONE PROCESSING CHANNEL to a Hop or Start Hold-Off Counter ). thod to synchronize the start of channels via microprocessor control: 1. Place the channels in sleep mode (a hard AD6652 RESET pin forces all four DDC processing channels into sleep mode). − 1. If the chip or channels have not been completely programmed, write all other registers now. e clocked at ntageous to do so in the application. The time from when the DTACK 2. Write the start hold-off counter(s) (0x83) to a value from 1 to 216 3. Write the start bit and the applicable channel sync bit(s) high at External Address 5. This triggers the start hold-off counters to begin their count. The counters ar with the AD6652 CLK signal. When it reaches a count of one, the sleep bits of the selected channels are set low to turn on the channel with the new or existing operating parameters. Note: Each channel has a redundant soft-sync control register Address 0x81. This register mimics the programming as set in the External Memory Address 5:5–4. The user can control the soft-sync function of a DDC channel by writing to the 0x81 register, if it is adva pin goes high (which acknowledges t data) to he receipt of the soft sync command when the DDC channel begins processing data is equal to the time period set up by the start hold-off counter value at 0x83 plus six CLK cycles. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |