| Datenblatt-Suchmaschine für elektronische Bauteile |
|
CS4525 Datenblatt(PDF) 80 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS4525 Datenblatt(HTML) 80 Page - Cirrus Logic |
|
80 / 98 page ![]() 80 DS726PP1 CS4525 9.10 Volume and 2-Way Cross-Over Configuration (Address 55h) 9.10.1 Soft Ramp and Zero Cross Control (SZCMode[1:0]) Default = 10 Function: Sets the soft ramp and zero crossing detection modes by which volume and muting changes will be im- plemented. 9.10.2 Enable 50% Duty Cycle for Mute Condition (Mute50/50) Default = 0 Function: When set, the amplifiers will output a non-modulated 50%-duty-cycle signal for all mute conditions. This bit does not cause a mute condition to occur. The Mute50/50 bit only defines operation during a normal mute condition. 9.10.3 Auto-Mute (AutoMute) Default = 1 Function: When enabled, the outputs of the CS4525 will mute following the reception of 8192 consecutive audio samples of static 0 or -1. A single sample of non-static data will release the mute. Detection and muting is done independently for each channel. See “Volume and Muting Control” on page 36 for more informa- tion. 76 543 21 0 SZCMode1 SZCMode0 Mute50/50 AutoMute En2Way 2WayFreq2 2WayFreq1 2WayFreq0 SZCMode[1:0] Setting Soft Ramp & Zero Crossing Mode 00 ........................................Immediate Change When immediate change is selected, all level changes will take effect immediately in one step. 01 ........................................Zero Cross Zero cross dictates that signal level changes, both muting and attenuation, will occur on a signal zero crossing to minimize audible artifacts. The requested level change will occur after a timeout period (approximately 18.7 ms for a PWM switch rate of 384/768 kHz and 17.0 ms for a PWM switch rate of 421.875/843.75 kHz) if the signal does not encounter a zero crossing. The zero cross function is independently monitored and implemented for each channel. 10 ........................................Soft Ramp Soft ramp allows level changes, both muting and attenuation, to be implemented by incrementally ramping, in ½ dB steps, from the current level to the new level at a rate of ½ dB per 4 sample peri- ods for 32, 44.1, and 48 kHz, and ½ dB per 8 sample periods for 96 kHz. 11.........................................Soft Ramp on Zero Cross Soft ramp on zero cross dictates that signal level changes, both muting and attenuation, will occur in ½ dB steps and be implemented on a signal zero crossing. The ½ dB level change will occur after a timeout period (approximately 18.7 ms for a PWM switch rate of 384/768 kHz and 17.0 ms for a PWM switch rate of 421.875/843.75 kHz) if the signal does not encounter a zero crossing. The zero cross function is independently monitored and implemented for each channel. Mute50/50 Setting 50% Duty Cycle Mute State 0 ..........................................50% duty cycle for mute conditions disabled. 1 ..........................................50% duty cycle for mute conditions enabled. AutoMute Setting AutoMute State 0 ..........................................Auto-mute on static 0’s or -1’s disabled. 1 ..........................................Auto-mute on static 0’s or -1’s enabled. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |