Back Button CMV2000 Datasheet HTML 72Page - ams-OSRAM AG CMV2000 Datasheet HTML 73Page - ams-OSRAM AG CMV2000 Datasheet HTML 74Page - ams-OSRAM AG CMV2000 Datasheet HTML 75Page - ams-OSRAM AG CMV2000 Datasheet HTML 76Page - ams-OSRAM AG CMV2000 Datasheet HTML 77Page - ams-OSRAM AG CMV2000 Datasheet HTML 78Page - ams-OSRAM AG CMV2000 Datasheet HTML 79Page - ams-OSRAM AG CMV2000 Datasheet HTML 80Page - ams-OSRAM AG Next Button
Zoom Inzoom in Zoom Outzoom out
 76 / 87 page
background image
CMV2000
Register description
Datasheet
• PUBLIC • Document Feedback
DS000734
• v8-00 • 2025-Jul-07
76 / 87
/
Table 36: Optical performance registers for version 2
Address
Name
Required value
Valid range
103[7:0]
ADC_GAIN
32
40 - 55
98[6:0]
V_ramp1
96
102 - 115
99[6:0]
V_ramp2
96
102 - 115
100[7:0]
Offset
16323
0 - 16383
Table 37: Optical performance registers for version 3
Address
Name
Required value
Valid range
103[7:0]
ADC_GAIN
See Gain chapter
0 - 63
98[6:0]
V_ramp1
109
102 - 115
99[6:0]
V_ramp2
109
102 - 115
100[7:0]
101[5:0]
Offset
16323
0 - 16383
To optimize the sensor response and minimize noise, the following procedure should be
followed for each sensor:
1. Start by programming all registers with the recommended values from the datasheet.
2. Take fully dark images with short exposure and calibrate the offset register so no pixel clips
in black (< 0DN).
3. When column non-uniformities are observed in the dark image, a calibration of the
V_ramp1 and V_ramp2 registers is necessary. These registers set the starting voltage of
the ramp used by the column ramp ADC, so adjusting this value will improve column CDS
(correlated double sampling) which will reduce the column FPN. Both values should be
adjusted together and should always have the same value.
4. Now take images with light and normal exposure. If the image is not saturated, increase the
light or the exposure time until all pixels reach a constant value. If not all pixels saturate at
1023 (meaning that the non-linear part of the pixel voltage is in the ADC input range),
increase the ADC gain/range setting until they do. The PGA amplifier can also be used at
this stage.
5. The dark offset level may have shifted when doing ADC calibration, so repeat step 2.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87


Datenblatt Download

Go To PDF Page


Link URL



War ALLDATASHEET hilfreich?  [ DONATE ] 

Über Alldatasheet   |   Werbung   |   Kontakt   |   Privatsphäre und Datenschutz   |   Link zum Datenblatt    |   Linktausch   |   Hersteller
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com