| Datenblatt-Suchmaschine für elektronische Bauteile |
|
CC1020-RTR1 Datenblatt(PDF) 51 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
CC1020-RTR1 Datenblatt(HTML) 51 Page - Texas Instruments |
|
51 / 95 page ![]() CC1020 www.ti.com SWRS046H – NOVEMBER 2006 – REVISED MARCH 2015 5.13 VCO and LNA Current Control The VCO current is programmable and should be set according to operating frequency, RX/TX mode and output power. Recommended settings for the VCO_CURRENT bits in the VCO register are shown in Table 5-16 and are also given by SmartRF Studio. The VCO current for frequency FREQ_A and FREQ_B can be programmed independently. The bias currents for the LNA, mixer and the LO and PA buffers are also programmable. The FRONTEND and the BUFF_CURRENT registers control these currents. 5.14 Power Management CC1020 offers great flexibility for power management in order to meet strict power consumption requirements in battery-operated applications. Power down mode is controlled through the MAIN register. There are separate bits to control the RX part, the TX part, the frequency synthesizer and the crystal oscillator in the MAIN register. This individual control can be used to optimize for lowest possible current consumption in each application. Figure 5-27 shows a typical power-on and initializing sequence for minimum power consumption. Figure 5-28 shows a typical sequence for activating RX and TX mode from power down mode for minimum power consumption. NOTE PSEL should be tri-stated or set to a high level during power down mode in order to prevent a trickle current from flowing in the internal pullup resistor. Application Note AN023 CC1020 MCU Interfacing (SWRA069) includes example source code. TI recommends resetting the CC1020 (by clearing the RESET_N bit in the MAIN register) when the chip is powered up initially. All registers that need to be configured should then be programmed (those which differ from their default values). Registers can be programmed freely in any order. The CC1020 should then be calibrated in both RX and TX mode. After this is completed, the CC1020 is ready for use. See the detailed procedure flowcharts in Figure 5-26 through Figure 5-28. With reference to Application Note AN023 CC1020 MCU Interfacing (SWRA069), TI recommends the following sequence: After power up: 1. ResetCC1020 2. Initialize 3. WakeUpCC1020ToRX 4. Calibrate 5. WakeUpCC1020ToTX 6. Calibrate After calibration is completed, enter TX mode (SetupCC1020TX), RX mode (SetupCC1020RX) or power down mode (SetupCC1020PD). From power-down mode to RX: 1. WakeUpCC1020ToRX 2. SetupCC1020RX Copyright © 2006–2015, Texas Instruments Incorporated Detailed Description 51 Submit Documentation Feedback Product Folder Links: CC1020 |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |