15 / 31 page ![]() 15 ENABLE/DISABLE OUTPUT CURRENT On the front panel, the LDD Enable and TC Enable buttons dictate whether or not output current is enabled. To enable either the LD or the TC current, push the corresponding button on the front panel. If output current is enabled, the LED will be lit (red for laser, blue for temperature control). There is no time delay before temperature output current is enabled after pushing the button. By default, there is a 2 second delay after pushing the LDD Enable button for current to be output to the laser. To disable current, press the corresponding Enable button again. Once the button is pushed, current will immediately disable, and the LED will become dark. DISPLAY EXISTING CURRENT AND VOLTAGE VALUES Press to access the Dual Monitor Screen. Values on this screen cannot be changed and are for information only. Figure 21. Dual Monitor Screen LD Current, LD Voltage, PD Power or PD Current (see Note below), and PD Bias Status are the laser parameters displayed. Temperature control parameters displayed include Actual Temperature, Sensor Voltage, TE Current (appropriately signed), and TE Voltage. If the temperature is within the defined tolerance, the target icon will be visible. NOTE: PD Current is displayed here if the PD Transfer Function (specified on the Photodiode Screen) is zero (OFF). PD Power is displayed here if the PD Transfer Function is nonzero. DISABLE CONDITIONS If certain operational parameters are exceeded or improperly configured, output current to the LD and/or TC will be disabled. Using the LASer:ENABle:OUTOFF remote command, the instrument can be configured to disable laser current if certain temperature conditions are not met. See "Independent/ Linked Operation" on page 27 for more information. • Load Open/Short: » The instrument will detect if there are open or shorted conditions across either the LD or the TC connections. The TC portion of the instrument will continue to operate if the laser portion malfunctions. Whether or not the LD portion of the instrument continues to operate if the TC portion malfunctions can be set by the user via remote commands. • Over- or Under-Temperature: » If the temperature limits that are set by the user are exceeded (either high or low), current to the thermoelectric will be disabled. Current to the laser can be disabled via remote commands. • Over- or Under-Voltage: » The LDTC LAB monitors the power supply voltages and triggers an error and shuts off the output if the internal power supplies are out of a pre-determined range. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |