| Datenblatt-Suchmaschine für elektronische Bauteile |
|
LDTC-LAB Datenblatt(PDF) 2 Page - Wavelength Electronics, Inc. |
|
|
|||||||||||||||||||||||||||||
LDTC-LAB Datenblatt(HTML) 2 Page - Wavelength Electronics, Inc. |
|
2 / 31 page ![]() 2 GENERAL OVERVIEW FEATURES LD250mTC5 LAB LD2TC5 LAB LD5TC10 LAB COMPLIANCE VOLTAGE (BOTH MODELS) LD 250 mA 2 A 5 A 10 V TC 5 A 5 A 10 A 15 V • Low-noise laser current, as low as 3µA, 7 μA, or 16 μA (100 kHz RMS) • Temperature stability better than 0.0009ºC with thermistor • Safety features protect your research » Adjustable current limits, with Brick-Wall Never-Exceed circuitry » Load failure protection » Temperature limits on the load » Current/voltage limits for both TEC and laser » Automatic laser shutdown upon TEC error available • Constant Current (Laser) or Constant Power (Photodiode Current) modes » Three photodiode ranges available: 0.5, 5, or 10 mA » Available photodiode bias voltage » Operates all laser diode/photodiode configurations • Compatible with a variety of temperature sensors » Thermistors and two-wire RTDs » Linear voltage and current sensors • Continuous Wave (CW) or Quasi-Continuous Wave (QCW) Operation • Also capable of driving LEDs • Modulation bandwidth 450kHz with external BNC input • Laser Diode voltage/current measurements • TEC voltage/current measurements • IntelliTune sets ideal PID control parameters for optimal time to temperature or fast disturbance rejection • Complete TMC command set for remote control from computer • LabVIEW® Virtual Instrument, USB interface • Field upgradeable firmware • Touchscreen with intuitive user interface • Data collection using a computer • Sophisticated error handling • Save and recall functions for specific set ups • Feature-rich for research projects LabVIEW is a trademark of National Instruments. ULTRA-STABLE TEMPERATURE CONTROLLER & LOW-NOISE LASER DRIVER The LDTC LAB series instruments combine best-in-class low noise, high-end digital control laser diode driver technology with an IntelliTune® smart temperature controller. If you need stable wavelength, stable temperature (better than 0.0009ºC with thermistors), stable laser diode current or power, or low noise (RMS laser driver noise as low as 3 µA), these offer the best performance and value. The touch-screen interface makes operation intuitive and simple. A LabVIEW® virtual instrument, remote command set, and USB interface allow integration into an instrument library. Safety features protect the thermoelectric cooler (TEC) and the laser. Over- and under-temperature limits, positive and negative (where applicable) current limits, and voltage limits can be set. If the sensor signal is lost or a short is detected at the TEC, output current is disabled. Passive and active interlocks are available for safety of equipment and user. You can link laser diode current to safe and stable thermoelectric operation. Operation in Constant Current (CC) or Constant Power (CP) mode changes with the touch of a button. A wide variety of sensors work in the temperature control feedback loop. INTELLITUNE®: INTELLIGENT AUTOTUNE Wavelength’s proprietary IntelliTune algorithm characterizes the TEC/sensor system’s response to the controller and determines the optimal PID control coefficients. It then automatically adjusts the PID control values as setpoint, tuning mode, or bias current change. Run IntelliTune easily just off ambient and watch it change PID settings for a much higher or lower setpoint.After a single scan, explore either optimized Setpoint Response or Disturbance Rejection performance with your load to see which works best. Add or remove the D term to see if noise is an issue. IntelliTune lets you skip the manual characterization, and it’s smart enough to really work—very little adjustment is needed after you have stored a successful characterization scan. See Application Note AN-TC13: IntelliTune® vs. Conventional Autotune for an in-depth exploration. APPLICATIONS The ultra-stable temperature controller/laser driver instruments are particularly reliable for diverse fields such as medical, defense, communications and manufacturing. Applications include particle and droplet measurement, communications, manufacturing test, and medical systems. Additionally, our products are designed for use with electro-optical systems, airborne instrumentation, spectroscopic monitors, and medical diagnostic equipment. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |