| Datenblatt-Suchmaschine für elektronische Bauteile |
|
LDTC-LAB Datenblatt(PDF) 27 Page - Wavelength Electronics, Inc. |
|
|
|||||||||||||||||||||||||||||
LDTC-LAB Datenblatt(HTML) 27 Page - Wavelength Electronics, Inc. |
|
27 / 31 page ![]() 27 ADDITIONAL TECHNICAL NOTES This section includes useful technical information on these topics: • Using the Max Laser Voltage Limit • Use Passive and Active ld Interlocks • Clipping LD Current Limit • Independent/Linked Operation USING THE MAX LASER VOLTAGE LIMIT The Maximum Laser Voltage field can be used as a safety feature, and a compliance voltage indicator. If the voltage across the laser attempts to breach the set limit, the instrument will present an error to keep the laser from operating in compliance voltage limited mode (not being able to achieve the full requested output current). USE PASSIVE AND ACTIVE LD INTERLOCKS The passive interlock is designed to trigger if Pins 2 and 3 on the LDD D-SUB are not shorted. Use this interlock with doors and enclosures that trigger an open circuit when opened. The active interlock (ACTIVE LOCK BNC) can be used with another active system component to disable/enable the LD current output. CLIPPING LD CURRENT LIMIT The LDTC LAB utilizes a clipping LD current limit. This means that at a current level very near the current limit, the instrument will clamp the output current at the limit, and continue operating at that level of output current. Output current will not be disabled if the limit is reached. INDEPENDENT/LINKED OPERATION The LDTC LAB can operate with the LD and TC sides independent of one another, or tied. If tied operation is chosen, the user can choose which TC errors will trigger a LD output current disable using the Laser Enable Output Off register (use remote command LASer:ENABle:OUTOFF). This register is defined below, in Table 7. DECIMAL HEXADECIMAL TC CONDITION 1 0x0001 Output disabled 2 0x0002 TEC short 4 0x0004 TEC open 8 0x0008 Temperature not stable 16 0x0010 Sensor short 32 0x0020 Sensor open 64 0x0040 Over-temperature 128 0x0080 Under-temperature Table 7. Laser Enable Output Off register definitions Each bit can be individually set. For example, if laser current needs to be shut down if there is a disconnection of the temperature sensor or if the temperature exceeds the maximum temperature limit, the set value would be 96 (sum of 32 for a sensor open condition and 64 for an over- temperature condition). Sending the remote command LAS:ENAB:OUTOFF 96 specifies this shutdown condition. By default, this register is set to zero, configuring for independent operation. For more information, see the LAB Series Instrument Command Set document. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |