| Datenblatt-Suchmaschine für elektronische Bauteile |
|
AS8515 Datenblatt(PDF) 15 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8515 Datenblatt(HTML) 15 Page - ams AG |
|
15 / 65 page ![]() www.ams.com Revision 0.7 15 - 65 AS8515 Datasheet - AS8515 To p Die Overview Note: L = Low state, H = High state, OT = Over temperature Reset, UVCC = Under-voltage VCC, UVSENSE = Under-voltage VSENSE, Rwake = Remote wake, X = don’t care. 7.10.1 Normal Mode This is the mode after the power-up. In this mode, voltage regulator, LIN transceiver, window Watchdog is all active. The resistive divider can be enabled through SPI. LIN transceiver is capable of sending the Tx data from microcontroller to the LIN bus at a maximum rate of 20Kbps. 7.10.2 Standby Mode Standby Mode is a functional low power mode and is entered by pulling EN to ground. The LIN transceiver, resistive divider, window watchdog, and Tx timeout watchdog circuits are disabled. But, it is possible to selectively enable the voltage and current measurement paths in this mode using an externally generated measurement enable (MEN) signal on the MEN pin. The timeout Watchdog can be enabled in this mode to make sure that the Microcontroller is active. 7.10.3 Temporary Shutdown Mode In this mode, the regulator is powered down and the VCC is pulled down. This provides an alternative way to reset those components powered by AS8515. The feature has to be enabled by the factory programming option and can be invoked through SPI. The LIN transceiver along with the LIN wake-up circuits are powered down. No remote wake functionality possible. LIN bus enters into recessive state. The system goes out of this mode to normal mode after the timeout of an internal timer. 7.10.4 Thermal Shutdown Mode If the junction temperature TJ is higher than Tsd, the device will be switched into the thermal shutdown mode. The regulator and the transceiver are completely disabled. Only the over-temperature monitor is active. As soon as the temperature returns back to TRET, the system enters normal mode. Table 15. Transition Table Transition Interface Reg. 0x05 D0 Flags Comments From Mode To Mode LIN Rx Tx EN Rwake UVSENSE OT UVCC Normal Mode Stand-By X-RS X-H1 1. Effect of transition H 2 2. Cause for transition H-L 2 L X X inactive inactive Tx is high for TSTNDY_trigger Temporary Shutdown X-RS X-H1 XH H 2 X X inactive set The Control Bit is set through the 4-Wire SPI interface Over- Temperature X-RS X-H1 XX L X X set set Temperature monitor output asserted (covered by scan) Standby Mode Normal (LW) X H-X 1 X L-H 2 L X X inactive inactive Normal (RW) X H-X 1 H X L set X inactive inactive Remote Wake up Event occurred on LIN Temporary Shutdown RS H 1 H L H 2 X X inactive set The Control bit is set through the 4-Wire SPI interface Over- Temperature RS H 1 HL L X X set set Temperature monitor output asserted (covered by scan) Temporary Shutdown Mode Normal RS-X H-X1 X X L X X inactive clear Internal 128ms timer expired Over- temperature Mode Normal RS-X H-X1 X X L X X clear clear Temperature monitor output de-asserted (covered by scan) All States Power Off X X X X X X L-H 2 XX |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |