| Datenblatt-Suchmaschine für elektronische Bauteile |
|
ATtiny45 Datenblatt(PDF) 42 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
ATtiny45 Datenblatt(HTML) 42 Page - ATMEL Corporation |
|
42 / 196 page ![]() 42 7598H–AVR–07/09 ATtiny25/45/85 8.9.1 Watchdog Timer Control Register – WDTCR • Bit 7 – WDIF: Watchdog Timeout Interrupt Flag This bit is set when a time-out occurs in the Watchdog Timer and the Watchdog Timer is config- ured for interrupt. WDIF is cleared by hardware when executing the corresponding interrupt handling vector. Alternatively, WDIF is cleared by writing a logic one to the flag. When the I-bit in SREG and WDIE are set, the Watchdog Time-out Interrupt is executed. • Bit 6 – WDIE: Watchdog Timeout Interrupt Enable When this bit is written to one, WDE is cleared, and the I-bit in the Status Register is set, the Watchdog Time-out Interrupt is enabled. In this mode the corresponding interrupt is executed instead of a reset if a timeout in the Watchdog Timer occurs. If WDE is set, WDIE is automatically cleared by hardware when a time-out occurs. This is useful for keeping the Watchdog Reset security while using the interrupt. After the WDIE bit is cleared, the next time-out will generate a reset. To avoid the Watchdog Reset, WDIE must be set after each interrupt. • Bit 4 – WDCE: Watchdog Change Enable This bit must be set when the WDE bit is written to logic zero. Otherwise, the Watchdog will not be disabled. Once written to one, hardware will clear this bit after four clock cycles. Refer to the description of the WDE bit for a Watchdog disable procedure. This bit must also be set when changing the prescaler bits. See “Timed Sequences for Changing the Configuration of the Watchdog Timer” on page 44. • Bit 3 – WDE: Watchdog Enable When the WDE is written to logic one, the Watchdog Timer is enabled, and if the WDE is written to logic zero, the Watchdog Timer function is disabled. WDE can only be cleared if the WDCE bit has logic level one. To disable an enabled Watchdog Timer, the following procedure must be followed: 1. In the same operation, write a logic one to WDCE and WDE. A logic one must be writ- ten to WDE even though it is set to one before the disable operation starts. 2. Within the next four clock cycles, write a logic 0 to WDE. This disables the Watchdog. In safety level 2, it is not possible to disable the Watchdog Timer, even with the algorithm described above. See “Timed Sequences for Changing the Configuration of the Watchdog Timer” on page 44. Bit 765 432 10 WDIF WDIE WDP3 WDCE WDE WDP2 WDP1 WDP0 WDTCR Read/Write R/W R/W R/W R/W R/W R/W R/W R/W Initial Value 0 0 0 0 X 0 0 0 Table 8-6. Watchdog Timer Configuration WDE WDIE Watchdog Timer State Action on Time-out 0 0 Stopped None 0 1 Running Interrupt 1 0 Running Reset 1 1 Running Interrupt |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |