WM8948ECS/R Datenblatt(PDF) 67 Page - Wolfson Microelectronics plc |
|
|
|||||||||||||||||||||||||||||
WM8948ECS/R Datenblatt(HTML) 67 Page - Wolfson Microelectronics plc |
|
67 / 189 page ![]() Production Data WM8948 w PD, May 2011, Rev 4.1 67 The Master Reference and Bias Control bits are defined in Table 40. REGISTER ADDRESS BIT LABEL DEFAULT DESCRIPTION R7 (07h) Additional control 10 VMID_REF_SEL 0 VMID Source Select 0 = LDO supply (LDOVDD) 1 = LDO output (LDOVOUT) 9 VMID_CTRL 0 VMID Ratio control Sets the ratio of VMID to the source selected by VMID_REF_SEL 0 = 5/11 1 = 1/2 4 VMID_ENA 0 VMID Enable 0 = Disabled 1 = Enabled R2 (02h) Power Management 1 3 BIAS_ENA 0 Master Bias Enable 0 = Disabled 1 = Enabled 1:0 VMID_SEL [1:0] 00 VMID Divider Enable and Select 00 = VMID disabled (for OFF mode) 01 = 2 x 50k Ω divider (for normal operation) 10 = 2 x 250k Ω divider (for low power standby) 11 = 2 x 5k Ω divider (for fast start- up) Table 40 Reference Voltages and Master Bias Enable A pop-suppressed start-up requires VMID to be enabled smoothly, without the step change normally associated with the initial stage of the VMID capacitor charging. A pop-suppressed start-up also requires the analogue bias current to be enabled throughout the signal path prior to the VMID reference voltage being applied. The WM8948 incorporates pop-suppression circuits which address these requirements. An alternate bias current source (Start-Up Bias) is provided for pop-free start-up; this is enabled by the STARTUP_BIAS_ENA register bit. The start-up bias is selected (in place of the normal bias) using the BIAS_SRC bit. It is recommended that the start-up bias is used during start-up, before switching back to the higher quality, normal bias. A soft-start circuit is provided in order to control the switch-on of the VMID reference. The soft-start control circuit offers two slew rates for enabling the VMID reference; these are selected and enabled by VMID_RAMP. When the soft-start circuit is enabled prior to enabling VMID_SEL, the reference voltage rises smoothly, without the step change that would otherwise occur. It is recommended that the soft-start circuit and the output signal path be enabled before VMID is enabled by VMID_SEL. A soft shut-down is provided, using the soft-start control circuit and the start-up bias current generator. The soft shut-down of VMID is achieved by setting VMID_RAMP, STARTUP_BIAS_ENA and BIAS_SRC to select the start-up bias current and soft-start circuit prior to setting VMID_SEL=00. The internal LDO (described in the previous section) requires a voltage reference. Under normal operating conditions, this is provided from VMID, via the register controls described in Table 40. Note, however, that VMID is normally generated from the LDO output. Therefore, an alternative voltage reference is required for start-up, which is not dependent on the LDO output. The VMID_FAST_START bit enables a ‘Fast-Start’ reference powered from LDOVDD. This alternate VMID can be selected as the LDO reference using the LDO_REF_SEL_FAST bit as described in Table 37. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |