93 / 189 page ![]() Production Data WM8948 w PD, May 2011, Rev 4.1 93 TOUCH PANEL CONTROLLER The WM8948 incorporates a Touch Panel controller interface, for use with standard 4-wire Touch Panels. The controller supports X, Y co-ordinate measurement, Pen Down detection and Touch Pressure (Z-axis) measurement. The Touch Panel controller provides high resolution digitiser measurements, using the same 12-bit AUXADC as described earlier (see “Auxiliary ADC”). Touch Panel conversion requests are interleaved with AUXADC measurement requests. Touch Panel Interrupts can be generated on completion of a set of measurements, or on Pen Down detection. Read access to the Touch Panel measurement data is controlled in order to ensure the host always reads a complete set of data, and does not read mixed data that relates to separate measurement events. An overview of Touch Panel operating principles is provided at the end of this section. TOUCH PANEL CONTROL The Touch Panel is enabled by setting the TCH_ENA register bit. The Touch Panel measurements can be initiated manually or automatically. For automatic operation, the TCH_RATE register is set according to the required conversion rate, and measurements are enabled by setting the TCH_CVT_ENA bit. For manual operation, the TCH_RATE register is set to 00h, and a set of measurements is initiated by setting the TCH_CVT_ENA bit. In manual mode, the TCH_CVT_ENA bit is reset by the WM8948 after each conversion request. The Touch Panel ‘Pen Down’ detection can be used to control measurements in automatic mode. When TCH_PDONLY is set, then automatic conversions will only be scheduled when ‘Pen Down’ is detected. Note that manual conversion commands are not affected by TCH_PDONLY. For each Touch Panel measurement event (in Manual or Automatic modes), the WM8948 performs a set of measurements encompassing all enabled input sources; the X-axis, Y-axis and Z-axis measurements are enabled using the TCH_X_ENA, TCH_Y_ENA and TCH_Z_ENA register bits respectively. To allow settling time between consecutive measurements, a programmable delay is applied between the X, Y and Z-axis measurements; this is set using the TCH_DELAY field. Pressure measurement uses a constant current source to measure the resistance between the top and bottom sheets of the touch panel. The current is selectable using TCH_ISEL, to suit different types of touch panel. Pen Down detection sensitivity can be controlled using TCH_RPU. Decreasing the resistance makes the touch panel less sensitive; increasing the resistance makes the touch panel more sensitive. The control fields associated with initiating Touch Panel measurements are defined in Table 60. REGISTER ADDRESS BIT LABEL DEFAULT DESCRIPTION R55 (37h) Touch Control 1 15 TCH_ENA 0 Touch Panel Enable 0 = Disabled 1 = Enabled 14 TCH_CVT_ENA 0 Touch Panel Conversion Enable 0 = Disabled 1 = Enabled In automatic mode, conversions are enabled by setting this bit. In manual mode (TCH_RATE = 0), setting this bit will initiate a set of conversion; the bit is reset automatically. 10 TCH_Z_ENA 0 Enables Z-axis touch panel measurements. 0 = Disabled 1 = Enabled |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |