| Datenblatt-Suchmaschine für elektronische Bauteile |
|
CC1020-RTR1 Datenblatt(PDF) 53 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
CC1020-RTR1 Datenblatt(HTML) 53 Page - Texas Instruments |
|
53 / 91 page ![]() CC1020 SWRS046 Page 53 of 92 C6 [nF] C7 [pF] C8 [pF] R2 [kΩ] R3 [kΩ] PLL turn-on time [us] Comment 220 8200 2200 1.5 4.7 3200 Up to 4.8 kBaud data rate, 12.5 kHz channel spacing 100 3900 1000 2.2 6.8 2500 Up to 4.8 kBaud data rate, 25 kHz channel spacing 56 2200 560 3.3 10 1400 Up to 9.6 kBaud data rate, 50 kHz channel spacing 15 560 150 5.6 18 1300 Up to 19.2 kBaud data rate, 100 kHz channel spacing 3.9 120 33 12 39 1080 Up to 38.4 kBaud data rate, 150 kHz channel spacing 1.0 27 3.3 27 82 950 Up to 76.8 kBaud data rate, 200 kHz channel spacing 0.2 1.5 - 47 150 700 Up to 153.6 kBaud data rate, 500 kHz channel spacing Table 25. Typical PLL turn-on time to within ±10% of channel spacing for different loop filter bandwidths 15.4. PLL Lock Time versus Loop Filter Bandwidth If calibration has been performed the PLL lock time is the time needed for the PLL to lock to the desired frequency when going from RX to TX mode or vice versa. The PLL lock time depends on the PLL loop filter bandwidth. Table 26 gives the PLL lock time for different PLL loop filter bandwidths. PLL lock time [us] C6 [nF] C7 [pF] C8 [pF] R2 [kΩ] R3 [kΩ] 1 2 3 Comment 220 8200 2200 1.5 4.7 900 180 1300 Up to 4.8 kBaud data rate, 12.5 kHz channel spacing 100 3900 1000 2.2 6.8 640 270 830 Up to 4.8 kBaud data rate, 25 kHz channel spacing 56 2200 560 3.3 10 400 140 490 Up to 9.6 kBaud data rate, 50 kHz channel spacing 15 560 150 5.6 18 140 70 230 Up to 19.2 kBaud data rate, 100 kHz channel spacing 3.9 120 33 12 39 75 50 180 Up to 38.4 kBaud data rate, 150 kHz channel spacing 1.0 27 3.3 27 82 30 15 55 Up to 76.8 kBaud data rate, 200 kHz channel spacing 0.2 1.5 - 47 150 14 14 28 Up to 153.6 kBaud data rate, 500 kHz channel spacing Table 26. Typical PLL lock time to within ±10% of channel spacing for different loop filter bandwidths. 1) 307.2 kHz step, 2) 1 channel step, 3) 1 MHz step 16. VCO and LNA Current Control The VCO current is programmable and should be set according to operating frequency, RX/TX mode and output power. Recommended settings for the VCO_CURRENT bits in the VCO register are shown in the register overview and also given by SmartRF® Studio. The VCO current for frequency FREQ_A and FREQ_B can be programmed independently. The bias currents for the LNA, mixer and the LO and PA buffers are also programmable. The FRONTEND and the BUFF_CURRENT registers control these currents. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |