95 / 221 page ![]() 95 www.national.com 3.6.3 The DUMPREG Command The DUMPREG command supports system run-time diagnostics, and application software development and debugging. DUMPREG has a one-byte command phase (the op- code) and a 10-byte result phase, which returns the values of parameters set in other commands. See the commands that set each parameter for a detailed de- scription of the parameter. Command Phase Execution Phase Internal registers read. Result Phase After a hardware or software reset, parameters in this phase are reset to their default values. Some of these parameters are unaffected by a software reset, de- pending on the state of the LOCK bit. See the command that determines the setting for the bit or field for details. First through Fourth Result Phase Bytes, Bits 7-0, Present Track Number (PTR) Drives 3-0 Each of these bytes contains either the internal 8- bit track number or the least significant byte of the 12-bit track number of the corresponding logical disk drive. Fifth and Sixth Result Phase Bytes, Bits 7-0, Step Rate Time, Motor Off Time, Motor On Time and DMA These fields are all set by the SPECIFY command. See Section 3.6.21 on page 116. Seventh Result Phase Byte - Sectors Per Track or End of Track (EOT) This byte varies depending on what commands have been previously executed. If the last command issued was a FORMAT TRACK command, and no read or write com- mands have been issued since then, this byte con- tains the sectors per track value. If a read or a write command was executed more recently than a FORMAT TRACK command, this byte specifies the number of the sector at the End of the Track (EOT). Eighth Result Phase Byte Bit 7 - LOCK This bit controls how the other bits in this com- mand respond to a software reset. See page 100. The value of this is determined by bit 7 of the op- code of the LOCK command. 0 -Bits in this command are set to their default values after a software reset. (Default) 1 - Bits in this command are unaffected by a soft- ware reset. Bits 5-0 - DC3-0, GDC Bits 5-0 of the second command phase byte of the PERPENDICULAR MODE command set bits 5-0 of this byte. See page 105. Ninth and Tenth Result Phase Bytes These bytes reflect the values in the third and fourth command phase bytes of the CONFIGURE command. See page 94. 7654 3210 0000 1110 7654 3210 Byte of Present Track Number (PTR) Drive 0 Byte of Present Track Number (PTR) Drive 1 Byte of Present Track Number (PTR) Drive 2 Byte of Present Track Number (PTR) Drive 3 Step Rate Time (SRT) Delay After Processing Delay Before Processing DMA Sectors per Track or End of Track (EOT) Sector # LOCK 0 DC3 DC2 DC1 DC0 GDC 0 EIS FIFO POLL THRESH Precompensation Track Number (PRETRK) |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |