| Datenblatt-Suchmaschine für elektronische Bauteile |
|
WM8994ECS/R Datenblatt(PDF) 139 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
WM8994ECS/R Datenblatt(HTML) 139 Page - Cirrus Logic |
|
139 / 363 page ![]() WM8994 Rev 4.6 139 Writing a logic 1 to DCS_TRIG_SINGLE_n initiates a single DC offset measurement and adjustment to the a ssociated output; (‘n’ = 0 for Left channel, 1 for Right channel). This will adjust the DC offset correction on the selected channel by no more than 1LSB (0.25mV). Setting DCS_TIMER_PERIOD_01 to a non-zero value will cause a single DC offset measurement and adjustment to be scheduled on a periodic basis. Periodic rates ranging from every 0.52s to in excess of 2 hours can be selected. Writing a logic 1 to DCS_TRIG_SERIES_n initiates a series of DC offset measurements and applies the necessary correction to the associated output. The number of DC Servo operations performed is determined by DCS_SERIES_NO_01. A maximum of 128 operations may be selected, though a much lower value will be sufficient in most applications. The DC Servo control fields associated with active modes (suitable for use on a signal path that is in active use) are described in Table 72. REGISTER ADDRESS BIT LABEL DEFAULT DESCRIPTION R84 (0054h) DC Servo (1) 13 DCS_TRIG_SINGLE _1 0 Writing 1 to this bit selects a single DC offset correction for HPOUT1R. In readback, a value of 1 indicates that the DC Servo single correction is in progress. 12 DCS_TRIG_SINGLE _0 0 Writing 1 to this bit selects a single DC offset correction for HPOUT1L. In readback, a value of 1 indicates that the DC Servo single correction is in progress. 9 DCS_TRIG_SERIES _1 0 Writing 1 to this bit selects a series of DC offset corrections for HPOUT1R. In readback, a value of 1 indicates that the DC Servo DAC Write correction is in progress. 8 DCS_TRIG_SERIES _0 0 Writing 1 to this bit selects a series of DC offset corrections for HPOUT1L. In readback, a value of 1 indicates that the DC Servo DAC Write correction is in progress. R85 (0055h) DC Servo (2) 11:5 DCS_SERIES_NO_ 01 [6:0] 010 1010 Number of DC Servo updates to perform in a series event. 0 = 1 update 1 = 2 updates ... 127 = 128 updates 3:0 DCS_TIMER_PERI OD_01 [3:0] 1010 Time between periodic updates. Time is calculated as 0.251s x (2^PERIOD), where PERIOD = DCS_TIMER_PERIOD_01. 0000 = Off 0001 = 0.502s …. 1010 = 257s (4min 17s) 1111 = 8225s (2hr 17min) Table 72 DC Servo Active Modes |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |