| Datenblatt-Suchmaschine für elektronische Bauteile |
|
SPSB100 Datenblatt(PDF) 19 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
SPSB100 Datenblatt(HTML) 19 Page - STMicroelectronics |
|
19 / 213 page ![]() BUCK2 can be disabled by the SPI bit VBUCK2_ENA. (only after SPI_PROTECT_ACCESS has been set). In active low power mode, the action of enable BUCK2 is not allowed. The live bit VBUCK2_ENA_STATUS reflects the state of BUCK2 output. Note: After the first power up is needed to align the live bit associated in DSR18 (VBUCK2_ENA_STATUS) with the current value associated in DCR1. In active full power BUCK2 converter provides the following diagnostics: • UV detection to monitor the output voltage (flag is BUCK2_UV). BUCK2 is therefore switched off after tbuck2_UV_TO except if SPI bit MASK_BUCK2_UV_POWER_OFF is set. • Undervoltage detection generates an IRQ except if MASK_BUCK2_IRQ is set. • OV detection to monitor the output voltage (flag is BUCK2_OV bit) BUCK2 is therefore switched off after tbuck2_OV_TO. Status register bit BUCK2_OV must be read and cleared before switching ON the regulator by SPI bit VBUCK2_ENA to allow a proper start-up (only when BUCK2 is not critical for MCU). • Overvoltage detection generates an IRQ except if MASK_BUCK2_IRQ is set. • Power-good used to signal BUCK power on success (flag is BUCK2_PG_OK bit and IRQ is generated except if MASK_BUCK2_PG_IRQ is set): – If not, after TBUCK2_PG_TO timing, BUCK2 is switched off and flag BUCK2_PG_TIMEOUT is set. • Not successful power-good detection generates an IRQ except if MASK_BUCK2_PG_TIMEOUT_IRQ is set. • Configurable overcurrent protection through U-NVM BUCK2_IPEAK(flag is BUCK2_OC bit). BUCK2 is therefore switched off after tbuck2_OC_TO except if MASK_BUCK2_OC_POWER_OFF is set. • Overcurrent detection generates an IRQ except if MASK_BUCK2_OC_IRQ is set. • Warning temperature detection by a local thermal sensor (flag is TW_CL2). • Warning temperature detection generates an IRQ except if MASK_CL2_TW_IRQ is set. • Overtemperature detection by a local thermal sensor (flag is TSD_CL2, see also the Section 4.7: Temperature monitoring) and BUCK2 is switched off. • BUCK2 internal regulators detection, flag is BUCK2_INT_FAIL and the BUCK2 is switched off. • Internal fail generates an IRQ except if MASK_BUCK2_IRQ is set. • BUCK2 Feedback (FB2) pin disconnection, flag is BUCK2_UV and the BUCK2 is switched off. • FB2 pin disconnection generates an IRQ except if MASK_BUCK2_IRQ is set. • After a fault detection (UV, OV,OC, FBLOSS, TSD_CL2 or PG timeout), BUCK2 can be re ‑enabled by setting BUCK2_ENA = 0 followed by BUCK2_ENA = 1. In active low power, BUCK2 converter provides the following diagnostics: • UV detection to monitor the output voltage (flag is BUCK2_UV). BUCK2 is therefore switched off except if SPI bit MASK_BUCK2_UV_POWER_OFF is set. • Undervoltage detection generates an IRQ except if MASK_BUCK2_IRQ is set. • OV detection to monitor the output voltage (flag is BUCK2_OV bit) BUCK2 is therefore switched off. • Overvoltage detection generates an IRQ except if MASK_BUCK2_IRQ is set. • Overcurrent protection (flag is BUCK2_OC bit). BUCK2 is therefore switched off except if MASK_BUCK2_OC_POWER_OFF is set. • Overcurrent detection generates an IRQ except if MASK_BUCK2_OC_IRQ is set. • BUCK2 feedback (FB2) pin disconnection, flag is BUCK2_FBLOSS and the BUCK2 is switched off. • FB2 pin disconnection generates an IRQ except if MASK_BUCK2_IRQ is set. • Overtemperature detection by a central thermal sensor (flag is TSD_CL0, see also the Section 4.7: Temperature monitoring) and device is executed power down sequence. In active and REC-1 states, when BUCK2_REGFAIL_GO_REC is set at 1 in USER-NVM, in case of PG timeout, OV, UV, INT_FAIL, OC, FBLOSS or TSD events the device executes a power down sequence, enters in REC-2 state and makes an automatic retry. PG_TIMEOUT, OV, UV, OC, INT_FAIL, FBLOSS or TSD flags are not blocking to re-enable the BUCK2 after a fail event. It is not recommended to use MASK_BUCK2_OC_POWER_OFF and MASK_BUCK2_UV_POWER_OFF in the same time. 3.3.3 BUCK3 converter BUCK3 is a postregulator and needs to be supplied by BUCK1 or BUCK2 through the VIN3 pin. SPSB100 Functional description DS14640 - Rev 2 page 19/213 |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |