| Datenblatt-Suchmaschine für elektronische Bauteile |
|
28HS01GTAM03 Datenblatt(PDF) 86 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
28HS01GTAM03 Datenblatt(HTML) 86 Page - Infineon Technologies AG |
|
86 / 138 page ![]() Datasheet 86 of 138 002-18216 Rev. *W 2022-01-18 256Mb/512Mb/1Gb SEMPER™ Flash Octal interface, 1.8V/3.0V Registers 5.11 Memory array data integrity check CRC register (DCRV) The memory array Data Integrity Check CRC Register (DCRV) stores the results of the CRC calculation on the data contained between the specified starting and ending addresses. 5.12 ECC status register (ESCV) The ECC Status Register (ESCV) contains the ECC status of any error correction action performed on the unit data whose byte was addressed during last read. Note Unit data is defined as the number of bytes over which the ECC is calculated. HL-T/HS-T family devices have a 16 bytes (128 bits) unit data. Table 57 Memory array data integrity check CRC register Bit number Name Function Read/Write N = Nonvolatile V = Volatile Factory default (binary) Description DCRV[31:0] DTCRCV[31:0] Memory Array Data CRC Checksum Value V -> R 0x00000000 Description: The DTCRCV[31:0 bits store the checksum value of the CRC process on the memory array data contained within the starting address and the ending address. Selection Options: Checksum Value Dependency: N/A Table 58 ECC status register Bit number Name Function Read/Write N = Nonvolatile V = Volatile Factory default (binary) Description ECSV[7:5] RESRVD Reserved for Future Use V -> R 000 This bit is Reserved for future use. This bit must always be written/loaded to its default state. ECSV[4] ECC2BT ECC Error 2-bit Error Detection Flag V -> R 0 Description: The ECC2BT bit indicates that a 2-bit ECC Error was detected in the data unit (16 bytes). A Clear ECC Status Register transaction (CLECC_0_0) will reset ECC2BT. Note ECC2BT is updated every time any memory address is read and is sticky, i.e. once it is set, it remains set. The ECC2BT status is maintained until a Clear ECC Status Register transaction (CLECC_0_0) is executed. Note ECC1BT is not valid if ECC2BT status flag is set. Selection Options: 0 = No 2-Bit ECC Error was detected in the data unit (16 bytes) 1 = 2-bit ECC Error was detected in the data unit (16 bytes) Dependency: CFR4x[3] ECSV[3] ECC1BT ECC Error 1-bit Error Detection and Correction Flag V -> R 0 Description: The ECC1BT bit indicates that a 1-bit ECC Error was detected and corrected in the data unit (16 bytes). A Clear ECC Status Register transaction (CLECC_0_0) will reset ECC1BT. Note ECC1BT is updated every time any memory address is read and is sticky, i.e. once it is set, it remains set. The ECC1BT status is maintained until a Clear ECC Status Register transaction (CLECC_0_0) is executed. Selection Options: 0 = No 1-Bit ECC Error was detected in the data unit (16 bytes) 1 = 1-bit ECC Error was detected in the data unit (16 bytes) Dependency: N/A ECSV[2:0] RESRVD Reserved for Future Use V -> R 000 This bit is Reserved for future use. This bit must always be written/loaded to its default state. |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |