| Datenblatt-Suchmaschine für elektronische Bauteile |
|
28HS01GTAM03 Datenblatt(PDF) 87 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
28HS01GTAM03 Datenblatt(HTML) 87 Page - Infineon Technologies AG |
|
87 / 138 page ![]() Datasheet 87 of 138 002-18216 Rev. *W 2022-01-18 256Mb/512Mb/1Gb SEMPER™ Flash Octal interface, 1.8V/3.0V Registers 5.13 ECC address trap register (EATV) The ECC Address Trap Register (EATV) stores the address of the ECC unit data where either a 1-Bit/2-Bit error or only a 1-Bit error occurred during a read operation. It stores the ECC unit address of the first ECC error captured during a memory read operation since the last Clear ECC transaction. 5.14 ECC error detection count register (ECTV) The ECC Error Detection Counter Register (ECTV) stores the number of either 1-Bit/2-Bit or only 1-Bit ECC errors have occurred during read operations since the last POR or hardware/software reset. Table 59 ECC address trap register Bit number Name Function Read/Write N = Nonvolatile V = Volatile Factory default (binary) Description EATV[31:0] ECCATP[31:0] ECC 1-bit and 2-bit Error Address Trap Register V -> R 0x00000000 Description: The Address Trap Register (ECCATP[31:0]) stores the ECC unit data address where a 1-Bit/2-Bit error occurred during a read operation. ECCATP[31:0] stores the ECC unit address of the first ECC error captured during a memory read operation since the last Clear ECC Status Register transaction (CLECC_0_0). Note ECCATP[31:0] is only updated during Read Instruction. Note Mask non-valid upper ECCATP address bits from ECC unit address. Note Clear ECC Status Register transaction (CLECC_0_0), POR or Hardware/Software reset clears the EATV[31:0] to 0x00000000. Selection Options: ECC Error Data Unit Address Dependency: N/A Table 60 ECC count register Bit number Name Function Read/Write N = Nonvolatile V = Volatile Factory default (binary) Description ECTV[15:0] ECCCNT[15:0] ECC 1-bit and 2-bit Error Count Register V -> R 0x0000 Description: The ECCCNT[15:0] stores the number of 1-bit/2-bit ECC errors occurred during read operations since the last POR or hardware/software reset. Note ECCCNT[15:0] is only updated during Read Instruction. Note Only one ECC error is counted for each data unit. If multiple read transactions access the same unit data containing an ECC error, the ECCCNT[15:0] will increment each time the unit data is read. Note Once the count reaches 0xFFFF, the ECCCNT[15:0] will stop incrementing Note POR or Hardware/Software reset clears the ECCNT[15:0] to 0x0000. Selection Options: ECC Error Count Dependency: N/A |
|
Link URL |
| War ALLDATASHEET hilfreich? [ DONATE ] |
Über Alldatasheet | Werbung | Kontakt | Privatsphäre und Datenschutz | Link zum Datenblatt | Linktausch | Hersteller All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |